Table of Contents
Comparing Dry Type and Liquid Filled Transformers
Transformers are essential components in electrical systems, as they help to regulate voltage levels and ensure the safe and efficient transmission of electricity. When it comes to transformers, there are two main types that are commonly used: dry type transformers and liquid filled transformers. In this article, we will compare these two types of transformers and discuss their advantages and disadvantages.
Dry type transformers are filled with a solid insulation material, such as epoxy resin or cast resin. This insulation material helps to protect the transformer from moisture and contaminants, making it ideal for indoor applications where space is limited. Dry type transformers are also known for their low maintenance requirements and high efficiency. However, they are typically more expensive than liquid filled transformers and may not be suitable for high voltage applications.
| model | Rating\\u00a0capacity\\u00a0\\uff08KVA\\uff09 | Off-load\\u00a0losses\\uff08W\\uff09 | Voltage\\u00a0combination\\u00a0\\uff08KV\\uff09 | Load\\u00a0losses\\uff08W\\uff09 | Off-load\\u00a0current\\u00a0\\uff08%\\uff09 | Short-circuit\\u00a0voltage\\u00a0\\uff08%\\uff09 |
| S11-M-30 | 30 | 100 | 6,6.3,10,10.5,11/0.4 | 600 | 2.3 | 4.0 |
| S11-M-50 | 50 | 130 | 6,6.3,10,10.5,11/0.4 | 870 | 2.0 | 4.0 |
| S11-M-63 | 63 | 150 | 6,6.3,10,10.5,11/0.4 | 1040 | 1.9 | 4.0 |
| S11-M-80 | 80 | 180 | 6,6.3,10,10.5,11/0.4 | 1250 | 1.9 | 4.0 |
| S11-M-100 | 100 | 200 | 6,6.3,10,10.5,11/0.4 | 1500 | 1.8 | 4.0 |
| S11-M-125 | 125 | 240 | 6,6.3,10,10.5,11/0.4 | 1800 | 1.7 | 4.0 |
| S11-M-160 | 160 | 280 | 6,6.3,10,10.5,11/0.4 | 2200 | 1.6 | 4.0 |
| S11-M-200 | 200 | 340 | 6,6.3,10,10.5,11/0.4 | 2600 | 1.5 | 4.0 |
| S11-M-250 | 250 | 400 | 6,6.3,10,10.5,11/0.4 | 3050 | 1.4 | 4.0 |
| S11-M-315 | 315 | 480 | 6,6.3,10,10.5,11/0.4 | 3650 | 1.4 | 4.0 |
| S11-M-400 | 400 | 570 | 6,6.3,10,10.5,11/0.4 | 4300 | 1.3 | 4.0 |
| S11-M-500 | 500 | 680 | 6,6.3,10,10.5,11/0.4 | 5100 | 1.2 | 4.0 |
| S11-M-630 | 630 | 810 | 6,6.3,10,10.5,11/0.4 | 6200 | 1.1 | 4.5 |
| S11-M-800 | 800 | 980 | 6,6.3,10,10.5,11/0.4 | 7500 | 1.0 | 4.5 |
| S11-M-1000 | 1000 | 1150 | 6,6.3,10,10.5,11/0.4 | 10300 | 1.0 | 4.5 |
| S11-M-1250 | 1250 | 1360 | 6,6.3,10,10.5,11/0.4 | 12800 | 0.9 | 4.5 |
| S11-M-1600 | 1600 | 1640 | 6,6.3,10,10.5,11/0.4 | 14500 | 0.8 | 4.5 |
| S11-M-2000 | 2000 | 2280 | 6,6.3,10,10.5,11/0.4 | 17820 | 0.6 | 5.0 |
| S11-M-2500 | 2500 | 2700 | 6,6.3,10,10.5,11/0.4 | 20700 | 0.6 | 5.0 |
| S11-M-30- | 30 | 90 | 20,22/0.4 | 660 | 2.1 | 5.5 |
| S11-M-50- | 50 | 130 | 20,22/0.4 | 960 | 2 | 5.5 |
| S11-M-63- | 63 | 150 | 20,22/0.4 | 1145 | 1.9 | 5.5 |
| S11-M-80- | 80 | 180 | 20,22/0.4 | 1370 | 1.8 | 5.5 |
| S11-M-100- | 100 | 200 | 20,22/0.4 | 1650 | 1.6 | 5.5 |
| S11-M-125- | 125 | 240 | 20,22/0.4 | 1980 | 1.5 | 5.5 |
| S11-M-160- | 160 | 290 | 20,22/0.4 | 2420 | 1.4 | 5.5 |
| S11-M-200- | 200 | 330 | 20,22/0.4 | 2860 | 1.3 | 5.5 |
| S11-M-250- | 250 | 400 | 20,22/0.4 | 3350 | 1.2 | 5.5 |
| S11-M-315- | 315 | 480 | 20,22/0.4 | 4010 | 1.1 | 5.5 |
| S11-M-400- | 400 | 570 | 20,22/0.4 | 4730 | 1 | 5.5 |
| S11-M-500 | 500 | 680 | 20,22/0.4 | 5660 | 1 | 5.5 |
| S11-M-630 | 630 | 810 | 20,22/0.4 | 6820 | 0.9 | 6 |
| S11-M-800 | 800 | 980 | 20,22/0.4 | 8250 | 1.8 | 6 |
| S11-M-1000 | 1000 | 1150 | 20,22/0.4 | 11330 | 0.7 | 6 |
| S11-M-1250 | 1250 | 1350 | 20,22/0.4 | 13200 | 0.7 | 6 |
| S11-M-1600 | 1600 | 1630 | 20,22/0.4 | 15950 | 0.6 | 6 |
On the other hand, liquid filled transformers are filled with a dielectric fluid, such as mineral oil or silicone oil. This fluid helps to dissipate heat and insulate the transformer, making it suitable for high voltage applications and outdoor installations. Liquid filled transformers are also more cost-effective than dry type transformers and can handle higher power loads. However, they require regular maintenance to ensure the fluid is clean and free of contaminants.
When choosing between dry type and liquid filled transformers, it is important to consider the specific requirements of your application. If you need a transformer for indoor use or in a space-constrained environment, a dry type transformer may be the best option. On the other hand, if you need a transformer for outdoor use or in a high voltage application, a liquid filled transformer may be more suitable.
In China, there are many factories and suppliers that specialize in manufacturing both dry type and liquid filled transformers. These factories offer a wide range of transformers with varying performance and price points to meet the needs of different customers. Whether you are looking for a high-performance transformer for a critical application or a cost-effective transformer for a less demanding application, you can find a suitable option from a Chinese factory or supplier.

To help customers make informed decisions, many Chinese factories and suppliers provide detailed information about their transformers, including specifications, performance data, and pricing. Some factories even offer videos that showcase their manufacturing processes and quality control measures, giving customers a behind-the-scenes look at how their transformers are made.
In conclusion, when comparing dry type and liquid filled transformers, it is important to consider the specific requirements of your application and weigh the advantages and disadvantages of each type. Whether you choose a dry type transformer for its low maintenance requirements and high efficiency, or a liquid filled transformer for its cost-effectiveness and high power handling capabilities, you can find a suitable option from a Chinese factory or supplier. By doing your research and comparing different options, you can select the best transformer for your needs and ensure the safe and efficient operation of your electrical system.