Exploring the Differences Between Dry Type and Oil Filled Transformers
Transformers are essential components in the electrical distribution system, responsible for stepping up or stepping down voltage levels to ensure efficient power transmission. There are various types of transformers available in the market, each with its own set of advantages and disadvantages. Two common types of transformers are dry type and oil-filled transformers, each serving different purposes and applications.

Dry type transformers, as the name suggests, do not use any liquid for cooling or insulation. Instead, they rely on air or gas for cooling and solid insulation materials such as epoxy resin or fiberglass for insulation. These transformers are typically used in indoor applications where fire safety is a concern, as they do not pose the risk of oil leakage or fire hazards. Dry type transformers are also more environmentally friendly compared to oil-filled transformers, as they do not contain any hazardous liquids that can harm the environment.
On the other hand, oil-filled transformers use mineral oil as a cooling and insulation medium. These transformers are commonly used in outdoor applications, such as pole-mounted transformers, where the risk of fire is lower. Oil-filled transformers are more efficient in dissipating heat compared to dry type transformers, making them suitable for high-power applications. However, they require regular maintenance to ensure the oil is clean and free from contaminants, which can be a costly and time-consuming process.

When choosing between dry type and oil-filled transformers, it is essential to consider the specific requirements of the application. Dry type transformers are ideal for indoor applications where fire safety and environmental concerns are a priority. On the other hand, oil-filled transformers are better suited for outdoor applications where high power levels and efficient heat dissipation are required.
One of the leading manufacturers of transformers in China is Pole Mounted Transformer Co., Ltd. This company specializes in producing a wide range of transformers, including both dry type and oil-filled transformers. With a strong focus on quality and innovation, Pole Mounted Transformer Co., Ltd. has established itself as a trusted supplier of transformers in the global market.
In addition to manufacturing transformers, Pole Mounted Transformer Co., Ltd. is also committed to sustainability and environmental protection. The company has implemented eco-friendly practices in its production processes, such as using recycled materials and reducing energy consumption. By prioritizing sustainability, Pole Mounted Transformer Co., Ltd. is contributing to a greener and more sustainable future for the planet.
| Dry transfo\\u00a0 | Rating\\u00a0power\\u00a0\\uff08KVA\\uff09 | Voltage\\u00a0combination\\uff08KV\\uff09 | Off-load\\u00a0losses\\uff08W\\uff09 | Load\\u00a0losses\\uff08W\\uff09 | Off-load\\u00a0current\\u00a0\\uff08%\\uff09 | Short-circuit\\u00a0voltage\\u00a0\\uff08%\\uff09 |
| SC10-30 | 30 | 6,6.3,6.6,10,11/0.4 | 190 | 710 | 2.4 | 4.0 |
| SC10-50 | 50 | 6,6.3,6.6,10,11/0.4 | 270 | 1000 | 2.4 | 4.0 |
| SC10-80 | 80 | 6,6.3,6.6,10,11/0.4 | 370 | 1380 | 1.8 | 4.0 |
| SC10-100 | 100 | 6,6.3,6.6,10,11/0.4 | 400 | 1570 | 1.8 | 4.0 |
| SC10-125 | 125 | 6,6.3,6.6,10,11/0.4 | 470 | 1850 | 1.6 | 4.0 |
| SCB10-160 | 160 | 6,6.3,6.6,10,11/0.4 | 550 | 2130 | 1.6 | 4.0 |
| SCB10-200 | 200 | 6,6.3,6.6,10,11/0.4 | 630 | 2530 | 1.4 | 4.0 |
| SCB10-250 | 250 | 6,6.3,6.6,10,11/0.4 | 720 | 2760 | 1.4 | 4.0 |
| SCB10-315 | 315 | 6,6.3,6.6,10,11/0.4 | 880 | 3470 | 1.2 | 4.0 |
| SCB10-400 | 400 | 6,6.3,6.6,10,11/0.4 | 980 | 3990 | 1.2 | 4.0 |
| SCB10-500 | 500 | 6,6.3,6.6,10,11/0.4 | 1160 | 4880 | 1.2 | 4.0 |
| SCB10-630 | 630 | 6,6.3,6.6,10,11/0.4 | 1350 | 5880 | 1.0 | 4.0 |
| SCB10-630 | 630 | 6,6.3,6.6,10,11/0.4 | 1300 | 5960 | 1.0 | 6.0 |
| SCB10-800 | 800 | 6,6.3,6.6,10,11/0.4 | 1520 | 6960 | 1.0 | 6.0 |
| SCB10-1000 | 1000 | 6,6.3,6.6,10,11/0.4 | 1770 | 8130 | 1.0 | 6.0 |
| SCB10-1250 | 1250 | 6,6.3,6.6,10,11/0.4 | 2090 | 9690 | 1.0 | 6.0 |
| SCB10-1600 | 1600 | 6,6.3,6.6,10,11/0.4 | 2450 | 11730 | 1.0 | 6.0 |
| SCB10-2000 | 2000 | 6,6.3,6.6,10,11/0.4 | 3050 | 14450 | 0.8 | 6.0 |
| SCB10-2500 | 2500 | 6,6.3,6.6,10,11/0.4 | 3600 | 17170 | 0.8 | 6.0 |
| model | Rating\\u00a0power\\u00a0\\uff08KVA\\uff09 | Off-load\\u00a0losses\\uff08W\\uff09 | Voltage\\u00a0combination\\u00a0\\uff08KV\\uff09 | Load\\u00a0losses\\uff08W\\uff09 | Off-load\\u00a0current\\u00a0\\uff08%\\uff09 | Short-circuit\\u00a0impedance\\u00a0\\uff08%\\uff09 |
| S11-M-30 | 30 | 100 | 6,6.3,10,10.5,11/0.4 | 600 | 2.3 | 4.0 |
| S11-M-50 | 50 | 130 | 6,6.3,10,10.5,11/0.4 | 870 | 2.0 | 4.0 |
| S11-M-63 | 63 | 150 | 6,6.3,10,10.5,11/0.4 | 1040 | 1.9 | 4.0 |
| S11-M-80 | 80 | 180 | 6,6.3,10,10.5,11/0.4 | 1250 | 1.9 | 4.0 |
| S11-M-100 | 100 | 200 | 6,6.3,10,10.5,11/0.4 | 1500 | 1.8 | 4.0 |
| S11-M-125 | 125 | 240 | 6,6.3,10,10.5,11/0.4 | 1800 | 1.7 | 4.0 |
| S11-M-160 | 160 | 280 | 6,6.3,10,10.5,11/0.4 | 2200 | 1.6 | 4.0 |
| S11-M-200 | 200 | 340 | 6,6.3,10,10.5,11/0.4 | 2600 | 1.5 | 4.0 |
| S11-M-250 | 250 | 400 | 6,6.3,10,10.5,11/0.4 | 3050 | 1.4 | 4.0 |
| S11-M-315 | 315 | 480 | 6,6.3,10,10.5,11/0.4 | 3650 | 1.4 | 4.0 |
| S11-M-400 | 400 | 570 | 6,6.3,10,10.5,11/0.4 | 4300 | 1.3 | 4.0 |
| S11-M-500 | 500 | 680 | 6,6.3,10,10.5,11/0.4 | 5100 | 1.2 | 4.0 |
| S11-M-630 | 630 | 810 | 6,6.3,10,10.5,11/0.4 | 6200 | 1.1 | 4.5 |
| S11-M-800 | 800 | 980 | 6,6.3,10,10.5,11/0.4 | 7500 | 1.0 | 4.5 |
| S11-M-1000 | 1000 | 1150 | 6,6.3,10,10.5,11/0.4 | 10300 | 1.0 | 4.5 |
| S11-M-1250 | 1250 | 1360 | 6,6.3,10,10.5,11/0.4 | 12800 | 0.9 | 4.5 |
| S11-M-1600 | 1600 | 1640 | 6,6.3,10,10.5,11/0.4 | 14500 | 0.8 | 4.5 |
| S11-M-2000 | 2000 | 2280 | 6,6.3,10,10.5,11/0.4 | 17820 | 0.6 | 5.0 |
| S11-M-2500 | 2500 | 2700 | 6,6.3,10,10.5,11/0.4 | 20700 | 0.6 | 5.0 |
| S11-M-30- | 30 | 90 | 20,22/0.4 | 660 | 2.1 | 5.5 |
| S11-M-50- | 50 | 130 | 20,22/0.4 | 960 | 2 | 5.5 |
| S11-M-63- | 63 | 150 | 20,22/0.4 | 1145 | 1.9 | 5.5 |
| S11-M-80- | 80 | 180 | 20,22/0.4 | 1370 | 1.8 | 5.5 |
| S11-M-100- | 100 | 200 | 20,22/0.4 | 1650 | 1.6 | 5.5 |
| S11-M-125- | 125 | 240 | 20,22/0.4 | 1980 | 1.5 | 5.5 |
| S11-M-160- | 160 | 290 | 20,22/0.4 | 2420 | 1.4 | 5.5 |
| S11-M-200- | 200 | 330 | 20,22/0.4 | 2860 | 1.3 | 5.5 |
| S11-M-250- | 250 | 400 | 20,22/0.4 | 3350 | 1.2 | 5.5 |
| S11-M-315- | 315 | 480 | 20,22/0.4 | 4010 | 1.1 | 5.5 |
| S11-M-400- | 400 | 570 | 20,22/0.4 | 4730 | 1 | 5.5 |
| S11-M-500 | 500 | 680 | 20,22/0.4 | 5660 | 1 | 5.5 |
| S11-M-630 | 630 | 810 | 20,22/0.4 | 6820 | 0.9 | 6 |
| S11-M-800 | 800 | 980 | 20,22/0.4 | 8250 | 1.8 | 6 |
| S11-M-1000 | 1000 | 1150 | 20,22/0.4 | 11330 | 0.7 | 6 |
| S11-M-1250 | 1250 | 1350 | 20,22/0.4 | 13200 | 0.7 | 6 |
| S11-M-1600 | 1600 | 1630 | 20,22/0.4 | 15950 | 0.6 | 6 |
To learn more about the different types of transformers and their applications, Pole Mounted Transformer Co., Ltd. has created informative videos that explain the differences between dry type and oil-filled transformers. These videos provide valuable insights into the advantages and disadvantages of each type of transformer, helping customers make informed decisions when choosing the right transformer for their specific needs.
In conclusion, the choice between dry type and oil-filled transformers depends on the specific requirements of the application. While dry type transformers are ideal for indoor applications where fire safety and environmental concerns are a priority, oil-filled transformers are better suited for outdoor applications where high power levels and efficient heat dissipation are required. By partnering with a reputable manufacturer like Pole Mounted Transformer Co., Ltd., customers can access high-quality transformers that meet their specific needs while also contributing to a more sustainable future.